Products / aerisIQ
AERISIQ · CONNECTED INDOOR AIR QUALITY
More insight.
One device.
Combine the sensing metrics your application needs in one compact LoRaWAN device — the featured CO₂, particulate, formaldehyde, NO₂, temperature and humidity configuration, or a custom combination.
15 min
factory reporting
USB-C
or battery power
Class A
OTAA activation
FEATURED IAQ CONFIGURATION
aerisIQ specifications.
Multi-parameter air quality monitoring in one compact LoRaWAN device. Designed for ASHRAE 62.2 IAQ monitoring applications.
CO₂ · NDIR
0–2,000 ppm standard range; optional 5,000 / 10,000 ppm. Accuracy ±(30 ppm + 3% of reading) at 0–2,000 ppm. Resolution 1 ppm.
PM1.0 / PM2.5 / PM10 · Laser scattering
0–1,000 µg/m³. Accuracy ±10 µg/m³ at 1–100 µg/m³. Resolution 1 µg/m³.
Formaldehyde (HCHO) · Electrochemical
0–2,000 ppb. Accuracy ±20 ppb at 0–100 ppb. Resolution 1 ppb.
Nitrogen dioxide (NO₂) · Solid polymer electrochemical
0–10 ppm. Accuracy ±20 ppb at 0–100 ppb.
Temperature
−20 to +70°C. Accuracy ±0.5°C. Resolution 0.1°C.
Relative humidity
0–100% RH. Accuracy ±3% RH at 10–90% RH; ±5% RH outside that band. Resolution 0.5% RH.
CONFIGURE THE MEASUREMENTS YOU NEED
Additional sensing options.
Available measurements depend on the selected configuration; not all modules are included as standard or necessarily available together. Nesos will confirm module compatibility, power requirements and reporting settings for your project.
DIGITAL MOX
TVOC
1–2,000 µg/m³. Resolution 1 µg/m³.
ELECTROCHEMICAL
Ozone (O₃)
0–9,999 ppb. Accuracy ±10 ppb at 0–100 ppb.
SOLID POLYMER ELECTROCHEMICAL
Ammonia (NH₃)
0–100 ppm. Resolution 0.01 ppm.
SOLID POLYMER ELECTROCHEMICAL
Hydrogen sulphide (H₂S)
0–100 ppm. Resolution 0.01 ppm.
ELECTROCHEMICAL
Carbon monoxide (CO)
0–1,000 ppm. Accuracy ±5 ppm or 10% of reading.
SOLID POLYMER ELECTROCHEMICAL
Sulphur dioxide (SO₂)
1–20 ppm. Resolution 0.1 ppm.
SOLID POLYMER ELECTROCHEMICAL
Oxygen (O₂)
0–30% vol. Accuracy ±5% of full scale.
CATALYTIC COMBUSTION
Methane (CH₄)
0–100% LEL. Accuracy confirmed during specification.
SOLID POLYMER ELECTROCHEMICAL
Chlorine (Cl₂)
0–100 ppm. Accuracy confirmed during specification.
NDIR
Sulphur hexafluoride (SF₆)
0–2,000 ppm. Accuracy ±(30 ppm + 5% of reading).
PASSIVE INFRARED (PIR)
Motion / occupancy
Vacant / occupied status. Spectral response 5–14 µm.
PHOTODIODE
Light / illumination
0–60,000 lux, reported as six levels (0–5).
ANALOGUE MEMS MICROPHONE
Noise
48–90 dBA. Accuracy ±3 dBA Leq.
Connectivity & reporting
LoRaWAN Class A · OTAA activation · 15-minute factory reporting interval. Configurable sensing and reporting, ADR, and up to 18,000 stored historical records with retransmission.
Power
USB-C 5 V / 1 A or four replaceable 4,000 mAh ER18505 Li-SOCl₂ batteries.
Enclosure & installation
125 × 125 × 30 mm · IP30 · Wall mounting with screws or 3M adhesive.
Operating environment
−20 to +60°C · 10–90% RH, non-condensing. Operating limits differ from sensor measurement ranges.
Regional configurations
EU868, US915, AU915, AS923-1/2/3/4, CN470, RU864, IN865 and KR920.
Standards
Designed for ASHRAE 62.2 IAQ monitoring applications. Factory-configured 15-minute reporting supports the monitoring approach described in Appendix D.
Specify your aerisIQ.
Tell us which metrics you need, the required ranges, installation environment, preferred power supply, deployment country and indicative quantity.